***Note: Many local criminal codes can now be located under Chapter 10.60 SMC while others are now cited under the Revised Code of Washington (RCW), which was incorporated into the municipal code in 2022. (See SMC 10.58.010). Code Enforcement, including Noise Control and Animal Regulations are located in Chapters 10.62 through 10.74.

Home
Title 17F
Chapter 17F.090
Section 17F.090.080
 

Title 17F Construction Standards

Chapter 17F.090 Mechanical Code

Section 17F.090.080 Miscellaneous Requirements

  1. A new gas appliance is considered approved if marked or labeled with a distinctive trademark or name as a means of identification, which shows approval by AGA or UL and shows the rated heat input in BTUs per hour.
     
  2. Propane-fueled hot water heaters and heating appliances must be equipped with an AGA-approved complete shutoff type automatic pilot, unless the appliance is installed on the exterior of a building or in an uninhabited building when approved by the inspector.
     
  3. A used gas appliance may not be installed for use on a consumer’s premises until approved by the inspector and identified accordingly.
     
  4. No appliance may ever be fired or adjusted to pass a greater amount of gas than its rated capacity.

Date Passed: Monday, June 7, 2010

Effective Date: Thursday, July 1, 2010

ORD C34600 Section 18