Title 17C Land Use Standards
Chapter 17C.111 Resident ial Zones
Section 17C.111.600 Resid
ent ial Visitability Standards
Purpose.
The purpose of the following section is to encourage the development of housing units for people with disabilities by providing allowances for accessible design and design considerations.
Applicability.
The provisions of this section apply to resident ial development in all zones where permitted. These guidelines encourage resident ial development s to incorporate visitable designs into at least a portion of the provided units. Any development seeking a reasonable deviation pursuant to 17C.111.600(C) must comply with all standards of 17C.111.600(D) for the unit(s) intended to benefit from the accessibility features requiring the deviation, and clearly note on submitted plans how the project meets each visitable design element . Director may waive full compliance with 17C.111.600(D) in cases of retrofits, commensurate with the significance of changes being made.
To encourage the development of housing units for people with disabilities, the Planning Director may allow reasonable deviation from height, setback, and footprint coverage standards to install features that facilitate accessibility. Such facilities shall be in conformance with the city adopted Building Code.
Visitable designs are encouraged for resident ial development , whether or not such accessible design considerations are required by the city adopted Building Code due to unit count. Element s of a visitable dwelling design include:
Visitable ent rance. At least one ent rance that is accessible via a route that does not have any stairs between it and the street lot line or an on-site parking space. The slope of the route does not exceed 1:8 (one foot in height for every 8 feet in length).
Visitable bathroom. At least one bathroom with a sink and toilet is designed to accommodate an unobstructed circle that is at least 60-inches in diameter. As an alternative, the bathroom may be designed to accommodate an unobstructed area that is comprised of two rectangles that are at least 36 inches by 60 inches, and orient ed at right angles to each other. The visitable bathroom is on the same floor as the visitable ent rance or is accessible from the visitable ent rance via a ramp, elevator, or lift.
Visitable living area. There is at least 200 square feet of living area on the same floor as the visitable ent rance or 200 square feet of living area is accessible from the visitable ent rance via a ramp, elevator, or lift.
Visitable doors. All door openings between and including the visitable ent rance, visitable living area, and the visitable bathroom is at least 34 inches wide.
Visitable light switches and environment al controls. The first floor contains light switches and environment al controls that are no higher than 48 inches above the interior floor level and outlets.
Date Passed: Monday, November 20, 2023
Effective Date: Monday, January 1, 2024
ORD C36459 Section 16