Title 10 Regulation of Activities
Division V. Code Enforcement and Animal Regulations
Chapter 10.70 Noise Control
Section 10.70.070 Maximum Permissible Environmental Sound Levels
- Maximum Permissible Environmental Sounds.
For sound sources located within the city, no sound is permitted to exceed the maximum permissible exterior sound levels established by WAC 173-60. Maximum permissible sound levels are as follows:
EDNA of Noise Source
|
EDNA of Receiving Property
|
|
Class A (dBA)
|
Class B (dBA)
|
Class C (dBA)
|
Class A
|
55
|
57
|
60
|
Class B
|
57
|
60
|
65
|
Class C
|
60
|
65
|
70
|
Class A - Residential Zones
Class B - Commercial, Office, Retail Zones
Class C - Industrial Zones
|
- The maximum permissible sound levels established by this chapter are modified as follows:
-
- Reduce by ten dBA between the hours of ten p.m. to seven a.m. for receiving property in Class A EDNAs; and
-
- Increase for short duration for any receiving property at any time:
-
-
- Increase by five dBA for fifteen minutes (L08) in any one-hour period; or
-
-
- Increase by ten dBA for five minutes (L02) in any one-hour period; or
-
-
- Increase by fifteen dBA for one and a half minutes (Lmax) in any one-hour period; and
- Where a receiving property lies within more than one EDNA classification, the maximum permissible sound level shall be determined by the most noise sensitive EDNA zone.
- The point of measurement shall be at the property boundary of the receiving property.
- Enforcing authority: code enforcement and parking services or police department.
Date Passed: Monday, October 3, 2022
Effective Date: Monday, October 3, 2022
ORD C36289 Section 5