Title 17C Land Use Standards
Chapter 17C.355A Wireless Communication Facilities
Section 17C.355A.030 Towers
- Towers shall be located only in those areas and pursuant to the process described in SMC Tables 17C.355A.030-1 and 17C.355A.030-2, provided that towers that are proposed to be located in a residential zone or within 150 feet of a residential zone shall be subject to the siting priorities set forth for preferred tower locations in SMC 17C.355A.050.
Table 17C.355A.030-1
New Wireless Communication Tower Criteria
Allowed by Type II Permit
|
Zone Category
|
Located in Public Right-of-way (ROW)
|
Maximum Tower Height
|
Stealth
Design
|
Setback from Property Lines (does not apply within ROW)[2]
|
O & OR[1]
|
Yes
|
60'
|
Optional[1]
|
N/A
|
No
|
60'
|
Optional[1]
|
20'
|
NR, NMU
CC & CA[1]
|
Yes
|
60'
|
Optional[1]
|
N/A
|
No
|
60'
|
Optional[1]
|
20'
|
CB & GC[1]
|
Yes or No
|
70'
|
Optional[1]
|
20'
|
All DT[1]
|
Yes or No
(allowed in ROW only if
less than
or equal
to 70')
|
150'
|
Optional[1]
|
20'
|
Industrial[1]
|
Yes or No
(allowed in ROW only if
less than
or equal
to 70')
|
150'
|
Optional[1]
|
20'
|
[1] If an applicant wants to construct a tower in a residential zone or within 50’ of a residential zone, then a Type III process and stealth design are required. If an applicant wants to construct a tower within 51’ - 150’ of a residential zone, then a Type II process and stealth design are required. If an applicant wants to construct a tower beyond 150’ of a residential zone, then the review process is that which is required in the zone in which the tower is to be located.
[2] See exception for locations adjacent to a residence in SMC 17C.355A.070(B).
Table SMC 17C.355A.030-2
New Wireless Communication Tower Criteria
Allowed by Type III Conditional Use Permit
|
Zone Category
|
Located in Public Right-of-way (ROW)
|
Maximum Tower Height
|
Stealth
Design
|
Setback from Property Lines[2] (does not apply within ROW)
|
All R[1]
|
Yes or No
|
60’
|
Required
|
20’
|
|
|
|
|
|
O, OR, NR, NMU, CC & CA[1]
|
Yes or No
|
61' - 70'[3]
|
Optional[1]
|
20'
|
CB & GC[1]
|
Yes or No
|
71' - 90'[4]
|
Optional[1]
|
20'
|
[1] If an applicant wants to construct a tower in a residential zone or within 50’ of a residential zone, then stealth design is required.
[2] See exceptions for locations adjacent to a residence in SMC 17C.355A.070(B).
[3] An additional 20 feet in height is allowed if applicant uses stealth design.
[4] An additional 30 feet in height is allowed if applicant uses stealth design.
Date Passed: Monday, November 2, 2015
Effective Date: Monday, November 2, 2015
ORD C35312 Section 2